Press to save each value. Exit by holding SET or waiting 10 seconds.
The voltage level at which the device stops discharging (in discharge mode) or starts charging (in charge mode).
If you only find a Chinese manual: Use Google Lens (phone camera) to translate text in real-time.
Set (Upper Limit): The voltage at which the charger stops (Battery Full).
Connect the to the IN terminals and the load to the OUT terminals.
The XYCD-60 usually has two sets of output relays (Output 1 and Output 2). Each set typically has three terminals:
| Code | Function | Description | Range/Default | | :--- | :--- | :--- | :--- | | | Heating / Cooling Mode | Sets the relay to activate on temperature drop (Heating) or rise (Cooling). | H (Heating) / C (Cooling) | | P1 | Hysteresis (Dead Band) | The difference between stopping and starting. If set to 2.0°C, the relay activates at Set Temp - 2°C (Heating mode). | 0.1°C – 15.0°C | | P2 | Delay Protection | Prevents rapid cycling of compressor/relay. (e.g., wait 3 minutes before restarting). | 0 – 10 Minutes | | P3 | High Alarm | Audible alarm triggers if temp exceeds this limit. | Off / Temp Value | | P4 | Low Alarm | Audible alarm triggers if temp drops below this limit. | Off / Temp Value | | P5 | Calibration | Corrects sensor reading errors. If actual temp is 25°C and display shows 24°C, set P5 to +1.0. | -5.0°C to +5.0°C |
The module features two core programmatic profiles. Selecting the right profile dictates how the physical relay responds to voltage changes. 1. Charging Control Mode ( IN )